aortic valve predilatation with a small balloon, without rapid pacing, prior to transfemoral transcatheter aortic valve replacement

Clicks: 368
ID: 246940
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #14 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objectives. The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR) using aortic valve predilatation (AVPD) with a small, nonocclusive balloon. Background. Balloon aortic valvuloplasty (BAV) under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism. Methods. A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm) without rapid pacing. Procedural data and clinical outcomes were analyzed. Results. The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 13±9. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was 12±5 mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2%) with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure. Conclusion. In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.
Reference Key
shivaraju2018biomedaortic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Anupama Shivaraju;Christian Thilo;Neal Sawlani;Ilka Ott;Heribert Schunkert;Wolfgang von Scheidt;Adnan Kastrati;Albert Markus Kasel
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2018
DOI
10.1155/2018/1080597
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.