an indirect atomic absorption spectrometric determination of trifluoperazine hydrochloride in pharmaceutical formulations based on chelate formation with palladium(ii)

Clicks: 153
ID: 246649
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #127 of 235 articles by views in Journal of pharmaceutical and biomedical analysis

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A new application of an indirect atomic absorption spectrometric (AAS) method was offered for the assay of low concentration of trifluoperazine hydrochloride (TFPH) in pure and pharmaceutical dosage form with good accuracy and precision. The method is depended on the formation of metal complex between the drug (TFPH) and palladium(II) to form orange-yellowish product extractable in organic solvent prior to its aspiration into an air-acetylene flame and indirectly determined by AAS. Using AA responses, all experimental parameters such as, pH, concentration of palladium, reaction time, extraction time and phase ratio which affect the complexation and extraction of TFPH-Pd(II), have been investigated. Under optimized conditions, linearity was observed in the range of 0.5-17 μg mL-1 with detection limit (S/N) of 0.038 μg mL-1, precision in range of 1.18-1.92%, accuracy as the %Erel of 2.4% and recoveries ranged from 101.7 to 104% with mean value of 102.4±0.135. The proposed method was applied for the determination of TFPH in the drug stelazine by both direct calibration and standard additions procedures and found to be 4.88 and 4.87 mg per unite, respectively compared with the stated value of 5 mg per unite. This method is also compared statistically with direct determination by using UV-Vis spectrophotometric technique which is preformed in our laboratory and found to be insignificant at 95% confidence level. All statistical calculations were implemented via the chemsoftware Minitab version 11.
Reference Key
qasim2010e-journalan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ameen W. Qasim;Zuhair A. A. Khammas
Journal Journal of pharmaceutical and biomedical analysis
Year 2010
DOI
10.1155/2010/153861
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.