effect of axial pre-compression on lateral performance of masonry under cyclic loading
Clicks: 213
ID: 245110
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
213 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #22 of 33 articles by views in parkinson's disease
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Strengthening of masonry against seismic events is very essential and getting maximum attention of researchers around the globe. An extensive experimental program was carried out to study the in-plane lateral performance of un-reinforced masonry, strengthened and retrofitted masonry wall panels under lateral cyclic loading. Twenty tests were carried out; four tests under monotonic lateral loading, twelve tests under static cyclic loading and four tests under pure compression. The test results were analyzed in five groups and this paper presents the analysis of group 4, which deals with effect of axial pre-compression on masonry seismic performance. Three single leaf panels with aspect ratio of 0.67 having size 1.65x1.1m were constructed using same material and workmanship. All the three un-reinforced walls were tested under 0, 0.5 and 1.0MPa vertical pre-compression and displacement controlled static cyclic loading. The wall tested under 0.5MPa pre-compression was reference specimen. The key parameters studied were hysterics behavior, peak lateral load, ultimate lateral displacement, energy dissipation, ductility, response factor and damping ratio. It was observed that level of axial pre-compression has significant effect on lateral capacity, failure mode and performance of masonry. In case of zero pre-compression the lateral capacity was very less and wall went into rocking failure at early stages of loading. Increase in pre-compression to 1.0MPa enhanced the lateral capacity by a factor of 1.92 times. After analysis of test results, it is found that pre-compression has significant effect on lateral capacity, failure mode and performance of masonry. In case of zero pre-compression the lateral capacity was very less and wall went into rocking failure at early stages of loading. Increase in pre-compression to 1.0MPa enhanced the lateral capacity by a factor of 1.92 times. After analysis of test results, it is found that pre-compression has very significant effect on lateral strength, energy dissipation and overall seismic performance.
| Reference Key |
hassanfarooq2011mehraneffect
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Syed HassanFarooq;Muhammad Ilyas;Asadullah Qazi |
| Journal | parkinson's disease |
| Year | 2011 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.