a bidimensional system of facial movement analysis conception and reliability in adults

Clicks: 4
ID: 242910
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,313 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objective. To design a bidimensional facial movement measuring tool and study its reliability. Methods. We utilized the free video-analysis software Kinovea that can track preselected points during movements and measure two-point distances off-line. Three raters positioned facial markers on 10 healthy individuals and video-taped them during maximal bilateral contractions of frontalis, corrugator, orbicularis oculi, zygomaticus, orbicularis oris, and buccinator, on two occasions. Each rater also analyzed the first video twice, one week apart. For each muscle, intrarater reliability was measured by percent agreements (PA) and intraclass correlation coefficients (ICC) between two assessments of the same video one week apart and between assessments of two videos collected one week apart. Interrater reliability was measured by PA, ICC, and coefficients of variation (CV) between assessments of the first video-recording by the three raters. Results. Intrarater and interrater reliabilities were good to excellent for frontalis (PA and ICC > 70%; CV < 15%), moderate for orbicularis oculi, zygomaticus, and orbicularis oris, and poor for corrugator and buccinators. Discussion. Without formal prior training, the proposed method was reliable for frontalis in healthy subjects. Improved marker selection, training sessions, and testing reliability in patients with facial paresis may enhance reliability for orbicularis oculi, zygomaticus, and orbicularis oris.
Reference Key
baude2015biomeda Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Marjolaine Baude;Emilie Hutin;Jean-Michel Gracies
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2015
DOI
10.1155/2015/812961
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.