sensitivities, specificities, and predictive values of microbiological culture techniques for the diagnosis of prosthetic joint infection

Clicks: 192
ID: 242173
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #489 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background. Identifying the microorganism in a prosthetic joint infection is the key to appropriately targeting antimicrobial treatment. Despite the availability of various techniques, no single test is considered the definitive gold standard. Aim. Our aim was to determine the sensitivity, specificity, and positive/negative predictive values for a variety of culture techniques. Methods. We performed a retrospective case series of 219 patients undergoing revision surgery of their hip or knee replacement between May 2004 and February 2013. The patients were classified as either infected or noninfected according to criteria set out by the Musculoskeletal Infection Society. The number and type of samples taken intraoperatively varied between cases but included tissue samples and fluid sent in either blood culture vials or sterile containers. Results. The highest sensitivity was found with blood culture vials (0.85) compared to fluid in sterile containers (0.26) and tissues samples (0.32). Blood culture vials also had a better specificity and positive and negative predictive values profile. Conclusion. We conclude that, of the techniques studied, fluid in blood culture vials had the best profile for the correct identification of microorganisms and advocate its use.
Reference Key
jordan2014biomedsensitivities, Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Robert W. Jordan;Nicholas A. Smith;Adnan Saithna;Andrew P. Sprowson;Pedro Foguet
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2014
DOI
10.1155/2014/180416
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.