analysis of combined cycle power plants with chemical looping reforming of natural gas and pre-combustion co2 capture
Clicks: 245
ID: 241991
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
245 views
58 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #148 of 526 articles by views in acs combinatorial science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this paper, a gas-fired combined cycle power plant subjected to a pre-combustion CO2 capture method has been analysed under different design conditions and different heat integration options. The power plant configuration includes the chemical looping reforming (CLR) of natural gas (NG), water gas shift (WGS) process, CO2 capture and compression, and a hydrogen fuelled combined cycle to produce power. The process is denoted as a CLR-CC process. One of the main parameters that affects the performance of the process is the pressure for the CLR. The process is analysed at different design pressures for the CLR, i.e., 5, 10, 15, 18, 25 and 30 bar. It is observed that the net electrical efficiency increases with an increase in the design pressure in the CLR. Secondly, the type of steam generated from the cooling of process streams also effects the net electrical efficiency of the process. Out of the five different cases including the base case presented in this study, it is observed that the net electrical efficiency of CLR-CCs can be improved to 46.5% (lower heating value of NG basis) by producing high-pressure steam through heat recovery from the pre-combustion process streams and sending it to the Heat Recovery Steam Generator in the power plant.
| Reference Key |
nazir2018energiesanalysis
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Shareq Mohd Nazir;Olav Bolland;Shahriar Amini |
| Journal | acs combinatorial science |
| Year | 2018 |
| DOI |
10.3390/en11010147
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.