distributed multiple tuned mass dampers for wind vibration response control of high-rise building
Clicks: 138
ID: 241515
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
138 views
34 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #22 of 42 articles by views in Plant foods for human nutrition (Dordrecht, Netherlands)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Multiple tuned mass dampers (MTMDs) distributed along height of a high-rise building are investigated for their effectiveness in vibration response control. A 76-storey benchmark building is modeled as shear type structure with a lateral degree of freedom at each floor, and tuned mass dampers (TMDs) are installed at top/different floors. Suitable locations for installing the TMDs and their tuning frequencies are identified based, respectively, on the mode shapes and frequencies of the uncontrolled and controlled buildings. Multimode control strategy has been adopted, wherein each TMD is placed where the mode shape amplitude of the building is the largest or large in the particular mode being controlled and tuned with the corresponding modal frequency. Newmark’s method is used to solve the governing equations of motion for the structure. The performance of the distributed MTMDs (d-MTMDs) is compared with single tuned mass damper (STMD) and all the MTMDs placed at top floor. The variations of top floor acceleration and displacement under wind loads are computed to study the effectiveness of the MTMDs in vibration control of the high-rise building. It is concluded that the d-MTMDs are more effective to control wind induced vibration than the STMD and the MTMDs placed at top floor.
| Reference Key |
elias2014journaldistributed
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Said Elias;Vasant Matsagar |
| Journal | Plant foods for human nutrition (Dordrecht, Netherlands) |
| Year | 2014 |
| DOI |
10.1155/2014/198719
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.