evaluating calibration strategies for isotope ratio infrared spectroscopy for atmospheric 13co2 / 12co2 measurement

Clicks: 116
ID: 240752
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #142 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Isotope ratio infrared spectroscopy (IRIS) provides an in situ technique for measuring δ13C in atmospheric CO2. A number of methods have been proposed for calibrating the IRIS measurements, but few studies have systematically evaluated their accuracy for atmospheric applications. In this study, we carried out laboratory and ambient measurements with two commercial IRIS analyzers and compared the accuracy of four calibration strategies. We found that calibration based on the 12C and 13C mixing ratios (Bowling et al., 2003) and on linear interpolation of the measured delta using the mixing ratio of the major isotopologue (Lee et al., 2005) yielded accuracy better than 0.06‰. Over a 7-day atmospheric measurement in Beijing, the two analyzers agreed to within −0.02 ± 0.18‰ after proper calibration. However, even after calibration the difference between the two analyzers showed a slight correlation with concentration, and this concentration dependence propagated through the Keeling analysis, resulting in a much larger difference of 2.44‰ for the Keeling intercept. The high sensitivity of the Keeling analysis to the concentration dependence underscores the challenge of IRIS for atmospheric research.
Reference Key
wen2013atmosphericevaluating Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;X.-F. Wen;Y. Meng;X.-Y. Zhang;X.-M. Sun;X. Lee
Journal bioorganic & medicinal chemistry
Year 2013
DOI
10.5194/amt-6-1491-2013
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.