monitoring local regional hemodynamic signal changes during motor execution and motor imagery using near-infrared spectroscopy

Clicks: 277
ID: 240682
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #216 of 461 articles by views in Journal of clinical and experimental dentistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 461 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The aim of this study was to clarify the topographical localization of motor-related regional hemodynamic signal changes during motor execution (ME) and motor imagery (MI) by using near-infrared spectroscopy (NIRS), as this technique is more clinically expedient than established methods (e.g. fMRI). Twenty right-handed healthy subjects participated in this study. The experimental protocol was a blocked design consisting of 3 cycles of 20 s of task performance and 30 s of rest. The tapping sequence task was performed with their fingers under 4 conditions: ME and MI with the right or left hand. Hemodynamic brain activity was measured with NIRS to monitor changes in oxygenated hemoglobin (oxy-Hb) concentration. Oxy-Hb in the somatosensory motor cortex (SMC) increased significantly only during contralateral ME and showed a significant interaction between task and hand. There was a main effect of hand in the left SMC. Although there were no significant main effects or interactions in the supplemental motor area (SMA) and premotor area (PMA), oxy-Hb increased substantially under all conditions. These results clarified the topographical localization by motor-related regional hemodynamic signal changes during ME and MI by using NIRS.
Reference Key
eiso2016frontiersmonitoring Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Naoki eIso;Naoki eIso;Takefumi eMoriuchi;Takefumi eMoriuchi;Akira eSagari;Akira eSagari;Eiji eKitajima;Fumiko eIso;Koji eTanaka;Yasuki eKikuchi;Takayuki eTabira;Toshio eHigashi
Journal Journal of clinical and experimental dentistry
Year 2016
DOI
10.3389/fphys.2015.00416
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.