validation of mipas imk/iaa v5r_o3_224 ozone profiles
Clicks: 81
ID: 239792
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
24.0
/100
81 views
17 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #167 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We present the results of an extensive validation program of the
most recent version of ozone vertical profiles retrieved with the
IMK/IAA (Institute for Meteorology and Climate Research/Instituto de Astrofísica de Andalucía)
MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) research level 2 processor from version 5 spectral
level 1 data. The time period covered corresponds to the reduced
spectral resolution period of the MIPAS instrument, i.e., January
2005–April 2012. The comparison with satellite instruments includes
all post-2005 satellite limb and occultation sensors that have measured
the vertical profiles of tropospheric and stratospheric ozone:
ACE-FTS, GOMOS, HALOE, HIRDLS, MLS, OSIRIS, POAM, SAGE II,
SCIAMACHY, SMILES, and SMR. In addition, balloon-borne MkIV solar
occultation measurements and ground-based Umkehr measurements have
been included, as well as two nadir sensors: IASI and SBUV. For
each reference data set, bias determination and precision assessment
are performed. Better agreement with reference instruments than for the previous
data version, V5R_O3_220 (Laeng et al., 2014), is found: the known
high bias around the ozone vmr (volume mixing ratio) peak is significantly reduced and the
vertical resolution at 35 km has been improved. The agreement
with limb and solar occultation reference instruments
that have a known small bias vs. ozonesondes is within 7% in
the lower and middle stratosphere and 5% in the upper
troposphere. Around the ozone vmr peak, the agreement with most of
the satellite reference instruments is within 5%; this bias is as
low as 3% for ACE-FTS, MLS, OSIRIS, POAM and SBUV.
| Reference Key |
laeng2014atmosphericvalidation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;A. Laeng;U. Grabowski;T. von Clarmann;G. Stiller;N. Glatthor;M. Höpfner;S. Kellmann;M. Kiefer;A. Linden;S. Lossow;V. Sofieva;I. Petropavlovskikh;D. Hubert;T. Bathgate;P. Bernath;C. D. Boone;C. Clerbaux;P. Coheur;R. Damadeo;D. Degenstein;S. Frith;L. Froidevaux;J. Gille;K. Hoppel;M. McHugh;Y. Kasai;J. Lumpe;N. Rahpoe;G. Toon;T. Sano;M. Suzuki;J. Tamminen;J. Urban;J. Urban;K. Walker;M. Weber;J. Zawodny |