determination of oleanolic and ursolic acids in hedyotis diffusa using hyphenated ultrasound-assisted supercritical carbon dioxide extraction and chromatography
Clicks: 168
ID: 238762
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
168 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #587 of 899 articles by views in ACS applied materials & interfaces
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 899 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Oleanolic acid (OA) and ursolic acid (UA) were extracted from Hedyotis diffusa using a hyphenated procedure of ultrasound-assisted and supercritical carbon dioxide (HSC–CO2) extraction at different temperatures, pressures, cosolvent percentages, and SC–CO2 flow rates. The results indicated that these parameters significantly affected the extraction yield. The maximal yields of OA (0.917 mg/g of dry plant) and UA (3.540 mg/g of dry plant) were obtained at a dynamic extraction time of 110 min, a static extraction time of 15 min, 28.2 MPa, and 56°C with a 12.5% (v/v) cosolvent (ethanol/water = 82/18, v/v) and SC–CO2 flowing at 2.3 mL/min (STP). The extracted yields were then analyzed by high performance liquid chromatography (HPLC) to quantify the OA and UA. The present findings revealed that H. diffusa is a potential source of OA and UA. In addition, using the hyphenated procedure for extraction is a promising and alternative process for recovering OA and UA from H. diffusa at high concentrations.
| Reference Key |
wei2015evidence-baseddetermination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Ming-Chi Wei;Yu-Chiao Yang;Show-Jen Hong |
| Journal | ACS applied materials & interfaces |
| Year | 2015 |
| DOI |
10.1155/2015/450547
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.