Microwave sensor for the investigation of glucose-dependent reflection properties in aqueous samples.
Clicks: 261
ID: 23871
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
69.7
/100
261 views
180 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #3 of 4 articles by views in journal of medical engineering & technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The reported paper presents the development of a microwave sensor with a resonant frequency 2.4 GHz. The sensor is also demonstrated to investigate the variation in its response as a function of glucose concentration. The sensor could be used for the monitoring of blood glucose level in diabetics through non-invasive technology. The approach followed is based on the notion that, change in glucose concentration in the blood affects dielectric properties of blood which in turn produce an impact on reflection properties of the sensor. This effect on response of sensor will be ultimately used to estimate blood glucose concentration. The design specifications considered for the development of sensor are defined in the paper. The experimental setup for experiment and procedure employed for the investigation of the reflection properties of the sensor as a function of glucose concentration are also discussed in detail. The shift in resonance frequency and the change in the magnitude of the reflection coefficient of proposed sensor have been observed. The reported measurement results are the preliminary results in exploring the implementation of proposed sensor for non-invasive blood glucose monitoring.
| Reference Key |
singh2019microwavejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Singh, Satish;Singh, Rajesh;Sen, Kushal;Anand, Sneh; |
| Journal | journal of medical engineering & technology |
| Year | 2019 |
| DOI |
10.1080/03091902.2019.1653388
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.