deciphering the precision of stereo ikonos canopy height models for us forests with g-liht airborne lidar

Clicks: 236
ID: 238255
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #254 of 499 articles by views in Journal of pharmacological sciences

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 499 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Few studies have evaluated the precision of IKONOS stereo data for measuring forest canopy height. The high cost of airborne light detection and ranging (LiDAR) data collection for large area studies and the present lack of a spaceborne instrument lead to the need to explore other low cost options. The US Government currently has access to a large archive of commercial high-resolution imagery, which could be quite valuable to forest structure studies. At 1 m resolution, we here compared canopy height models (CHMs) and height data derived from Goddard’s airborne LiDAR Hyper-spectral and Thermal Imager (G-LiHT) with three types of IKONOS stereo derived digital surface models (DSMs) that estimate CHMs by subtracting National Elevation Data (NED) digital terrain models (DTMs). We found the following in three different forested regions of the US after excluding heterogeneous and disturbed forest samples: (1) G-LiHT DTMs were highly correlated with NED DTMs with R2 > 0.98 and root mean square errors (RMSEs) < 2.96 m; (2) when using one visually identifiable ground control point (GCP) from NED, G-LiHT DSMs and IKONOS DSMs had R2 > 0.84 and RMSEs of 2.7 to 4.1 m; and (3) one GCP CHMs for two study sites had R2 > 0.7 and RMSEs of 2.6 to 3 m where data were collected less than four years apart. Our results suggest that IKONOS stereo data are a useful LiDAR alternative where high-quality DTMs are available.
Reference Key
neigh2014remotedeciphering Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Christopher S. R. Neigh;Jeffrey G. Masek;Paul Bourget;Bruce Cook;Chengquan Huang;Khaldoun Rishmawi;Feng Zhao
Journal Journal of pharmacological sciences
Year 2014
DOI
10.3390/rs6031762
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.