PLUG-N-HARVEST Architecture for Secure and Intelligent Management of Near-Zero Energy Buildings.

Clicks: 196
ID: 23813
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,330 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Building Automation (BA) is key to encourage the growth of more sustainable cities and smart homes. However, current BA systems are not able to manage new constructions based on Adaptable/Dynamic Building Envelopes (ADBE) achieving near-zero energy-efficiency. The ADBE buildings integrate Renewable Energy Sources (RES) and Envelope Retrofitting (ER) that must be managed by new BA systems based on Artificial Intelligence (AI) and Internet of Things (IoT) through secure protocols. This paper presents the PLUG-N-HARVEST architecture based on cloud AI systems and security-by-design IoT networks to manage near-zero ADBE constructions in both residential and commercial buildings. To demonstrate the PLUG-N-HARVEST architecture, three different real-world pilots have been considered in Germany, Greece and Spain. The paper describes the Spain pilot of residential buildings including the deployment of IoT wireless networks (i.e., sensors and actuators) based on Zwave technology to enable plug-and-play installations. The real-world tests showed the high efficiency of security-by-design Internet communications between building equipment and cloud management systems. Moreover, the results of cloud intelligent management demonstrate the improvements in both energy consumption and comfort conditions.
Reference Key
marinperez2019plugnharvestsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Marin-Perez, Rafael;Michailidis, Iakovos T;Garcia-Carrillo, Dan;Korkas, Christos D;Kosmatopoulos, Elias B;Skarmeta, Antonio;
Journal sensors
Year 2019
DOI
E843
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.