correlation between t-wave alternans and cardiac volume status via intrathoracic impedance measurements

Clicks: 5
ID: 237992
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #71 of 73 articles by views in gastroenterology research and practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction. The presence of T-wave alternans (TWA) has been shown to correlate with a higher risk for sudden cardiac death. The mechanism of TWA may be related to abnormalities in intracellular calcium handling, which is a mechanism in heart failure and associated arrhythmias as well. However, an association between TWA and cardiac volume status has not been demonstrated. Methods Used. We report the case of a 54-year-old man with a dilated cardiomyopathy who had a biventricular defibrillator system implanted with intrathoracic impedance measurement capability. We performed baseline TWA testing, which was normal and was associated with normal clinical status and normal intrathoracic impedance. We followed intrathoracic impedance measurements, and when the measurement suggested volume overload eight months later, we repeated the TWA test. TWA was grossly positive, and volume overload was corroborated with clinical heart failure. The patient was diuresed, and when clinical status and intrathoracic impedance returned to normal a month later, we repeated TWA, which was again negative. Conclusion. This case demonstrates a correlation between cardiac volume status, as measured by intrathoracic impedance measurements, and TWA status. This data suggests that conditions of volume overload such as heart failure could be causally related to increased TWA, perhaps by the common mechanism of altered intracellular calcium handling.
Reference Key
dizon2012casecorrelation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Jose' Dizon;Kathleen Hickey;Hasan Garan
Journal gastroenterology research and practice
Year 2012
DOI
10.1155/2012/167562
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.