blood transfusion and oxygen extraction ratio in patients admitted to the general intensive care unit: a quasi experimental study
Clicks: 299
ID: 237455
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
299 views
44 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 48 articles by views in advances in optoelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Blood transfusion is commonly undertaken in critically ill patients; and studies have suggested the use of oxygen extraction ratio (O2ER) as an additional transfusion trigger in critically ill patients. The aim of this study was to establish the relationship between blood transfusion and oxygen extraction ratio in adult patients admitted to the general intensive care unit, using central venous oxygen saturation instead of mixed venous oxygen saturation.
Methods: Arterial and central venous blood samples were drawn and a blood gas analysis immediately before commencement of blood transfusion was undertaken. At least 15 min after completion of the transfusion, similar samples were drawn and the blood gas analysis was repeated. The O2ER before and after transfusion was then calculated. Using paired student’s t-test, we checked whether the mean difference between the two O2ERs was statistically significant.
Results: We enrolled 58 patients in the study, the mean (±SD) haemoglobin concentration before transfusion was 7.38 g/dl (±1.71). The mean change in haemoglobin concentration following blood transfusion was 2.29 g/dl (±1.18), after transfusing an average of 1.95 (±0.83) units of packed cells. Mean O2ER was 0.27 (±0.11) before, and 0.25 (±0.12) after RBC transfusion. The mean change in O2ER was −0.018 SD ± 0.10 (95% CI, −0.043–0.007; P = 0.15). Linear regression analysis showed no statistically significant relationship between change in haemoglobin concentration and change in O2ER; p-value = 0.12.
Discussion: The change in oxygen extraction ratio was not statistically significant following blood transfusion in adult patients admitted to the general ICU at a tertiary teaching hospital. Further studies are required especially in patients with increased pre transfusion O2ER to evaluate the usefulness of this measurement as a possible transfusion trigger.
| Reference Key |
mungayi2014africanblood
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Vitalis Mung’ayi;Thikra Sharif;David Samuel Odaba |
| Journal | advances in optoelectronics |