determinação visual do componente rápido do excesso do consumo de oxigênio após o exercício visual determination of the fast component of excessive oxygen uptake after exercise
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #47 of 73 articles by views in research disclosure
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
The objective of this study was to analyze the validity, reproducibility and objectivity of the visual inspection method during the identification of the fast component of excess post-exercise oxygen consumption (EPOC FAST). Ten healthy physically active men (age = 23.0 + 4.0 years; height = 176.4 + 6.8 cm; body mass = 72.4 + 8.2 kg; VO2MAX = 3.0 + 0.5 L.min-1) performed a maximal incremental exercise and a constant workload test until exhaustion corresponding to 110% of maximal workload reached during the maximal incremental exercise. Oxygen consumption was measured breath-by-breath for 10 minutes during the passive recovery after the constant workload test. EPOC FAST was mathematically and visually determined by three evaluators. Double visual determination of EPOC FAST was carried out by each evaluator for reproducibility determination. There were no significant differences between EPOCFAST values obtained by mathematical (0.98 ± 0.45 L) or visual method (1.04 ± 0.45 L; 1.02 ± 0.45 L and 1.02 ± 0.45 L). None significant difference was found between the first and second visual assessment carried out by the evaluators (evaluator 1: 1.04 ± 0.45 L vs 1.04 ± 0.49 L; evaluator 2: 1.02 ± 0.45 L vs 1.01 ± 0.44 L and evaluator 3: 1.02 ± 0.45 L vs 1.03 ± 0.47 L). Finally, coefficient of intra-class correlation between determinations was high for all evaluators (ICC from 0.97 to 0.99). These results suggest that the visual method is valid, objective and reproducible for determination of the EPOC FAST.
| Reference Key |
bertuzzi2010revistadeterminao
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | |
| Journal | research disclosure |
| Year | 2010 |
| DOI |
10.1590/S1517-86922010000200013
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.