highlights on novel technologies for the detection of antibodies to ro60, ro52, and ss-b
Clicks: 73
ID: 235078
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
21.6
/100
73 views
9 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #166 of 171 articles by views in Applied Surface Science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 171 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective. We aimed to compare a chemiluminescent immunoassay (CIA, QUANTA Flash) on BIO-FLASH with a multiplex flow immunoassay (MFI) on BioPlex 2200 for the detection of antibodies to Ro60, Ro52, and SS-B. Methods. The study included 241 samples, from patients suffering from systemic autoimmune diseases (n=108) as well as disease controls (n=133). All samples were tested for anti-Ro52, anti-Ro60, and anti-SS-B (La) antibodies on QUANTA Flash (INOVA Diagnostics, San Diego, USA) and BioPlex 2200 (Bio-Rad Laboratories Inc., Hercules, USA). Discrepant samples were tested by two independent methods: BlueDot/ANA and QUANTRIX Microarray (both D-tek, Belgium). Results. The overall qualitative agreements were 95.4% (95% confidence interval, CI 92.0–97.7%) for anti-Ro52, 98.8% (95% CI 96.4–99.7%) for anti-Ro60, and 91.7% (95% CI 87.5–94.9%) for anti-SS-B antibodies. There were 34 discrepant samples among all assays (20 anti-SS-B, 11 anti-Ro52, 3 anti-Ro60). 30/33 of retested samples (by D-tek dot blot) agreed with the QUANTA Flash results. Similar findings were obtained with QUANTRIX Microarray kit. Conclusion. QUANTA Flash and BioPlex 2200 show good qualitative agreement. The clinical performances were similar for anti-Ro52 and anti-Ro60 autoantibodies while differences were observed for anti-SS-B (La) antibodies.
| Reference Key |
infantino2013clinicalhighlights
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;M. Infantino;C. Bentow;A. Seaman;M. Benucci;F. Atzeni;P. Sarzi-Puttini;B. Olivito;F. Meacci;M. Manfredi;M. Mahler |
| Journal | Applied Surface Science |
| Year | 2013 |
| DOI |
10.1155/2013/978202
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.