high degree spondylolisthesis in adults: monosegmental reduction and fixation
Clicks: 73
ID: 233213
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
21.3
/100
73 views
8 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #33 of 39 articles by views in proceedings of the international conference on industrial engineering and operations management
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Objective:To evaluate a method to reduce high degree spondylolisthesis in adults with monosegmental fixing preserving the adjacent level and the improvement of sagittal balance.Methods:A prospective study, with 12 adult patients with high degree spondylolisthesis (III and IV) in adults who underwent surgery by the same team. We included 7 women and 5 men with a mean age of 37 years and lombosciatalgy that had no improvement with conservative treatment. The surgical technique used was total or partial reduction by Spondylolisthesis Reduction Instrument (SRI) system, with instrumentation only in the affected level, thus sparing the adjacent level, associated with 360ofusion.Results:The L5-S1 level was involved in nine patients, L4-L5 in two, and VT-S1 in one patient. The isthmic type predominated in nine patients, followed by dysplastic type in two, and one iatrogenic spondylolisthesis. These patients were assessed by the Oswestry scale, which showed a preoperative average of 59% and postoperative average of 12.4% (P<0.05). A significant improvement in the average slip angle from 54.66% to 9.5% (35% to 0%) was found. No major complications such as infection, neurological damage or material breaks were observed.Conclusion:The reduction of high degree listhesis instrumenting only the affected level produces good results, with good control of pain and functional improvement of patients. However, a larger follow-up is required to better evaluation.
| Reference Key |
abdala2015coluna/columnahigh
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Eduardo Henrique Chiovato Abdala;Ériko Gonçalves Filgueira;Luciano de Almeida Ferrer;João de Souza Nascimento Filho |
| Journal | proceedings of the international conference on industrial engineering and operations management |
| Year | 2015 |
| DOI |
10.1590/S1808-185120151403054375
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.