enzymatic measurement of ether phospholipids in human plasma after hydrolysis of plasma with phospholipase a1

Clicks: 292
ID: 233194
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #9 of 12 articles by views in biochemia medica

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objectives: Ethanolamine ether phospholipids (ePE) and choline ether phospholipid (ePC) are present in human serum or plasma. Decreases in ether phospholipids (plasmalogens) in serum (plasma) have been reported in several diseases such as Alzheimer's disease, Parkinson's disease, metabolic syndrome, schizophrenia. Therefore, need for assay of ether phospholipids in plasma may increase in the future. Nowadays, measurement of the ether phospholipids in human plasma seem to depend on tandem mass spectrometry (LC/MS/MS), but a system for LC/MS/MS is too expensive for most of ordinary clinical laboratories, moreover, use and maintenance of the system are time consuming. Design and methods: Phospholipase A1 (PLA1) hydrolyzes ester (acyl) bond at the sn-1 position of glycerophospholipids, but it does not act on ether bond at the sn-1 position. We confirmed by a HPLC method that treatment of plasma with PLA1 causes complete disappearance of all diacyl phospholipids, but ether phospholipids remain intact. On the basis of these observations, we developed an enzymatic assay method for ePE and ePC in human plasma by use of a fluorescence plate reader. Results: The amount of ePE in human plasma measured by the enzymatic method was well correlated to that by LC/ESI-MS method (R2 > 0.94), but the correlation of ePC between the two methods was bit poorer (R2 > 0.77) than that of ePE. Conclusion: The enzymatic method may be applied to assay of ether phospholipids (ePE and ePC) not only in human plasma but also to assay of ePE and ePC in the other tissues.
Reference Key
mawatari2018practicalenzymatic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Shiro Mawatari;Seira Hazeyama;Tomomi Morisaki;Takehiko Fujino
Journal biochemia medica
Year 2018
DOI
10.1016/j.plabm.2018.01.003
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.