a newly identified calculation discrepancy of the sunset semi-continuous carbon analyzer

Clicks: 86
ID: 232826
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #164 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The Sunset semi-continuous carbon analyzer (SCCA) is an instrument widely used for carbonaceous aerosol measurement. Despite previous validation work, in this study we identified a new type of SCCA calculation discrepancy caused by the default multipoint baseline correction method. When exceeding a certain threshold carbon load, multipoint correction could cause significant total carbon (TC) underestimation. This calculation discrepancy was characterized for both sucrose and ambient samples, with two protocols based on IMPROVE (Interagency Monitoring of PROtected Visual Environments) (i.e., IMPshort and IMPlong) and one NIOSH (National Institute for Occupational Safety and Health)-like protocol (rtNIOSH). For ambient samples, the IMPshort, IMPlong and rtNIOSH protocol underestimated 22, 36 and 12% of TC, respectively, with the corresponding threshold being ~ 0, 20 and 25 μgC. For sucrose, however, such discrepancy was observed only with the IMPshort protocol, indicating the need of more refractory SCCA calibration substance. Although the calculation discrepancy could be largely reduced by the single-point baseline correction method, the instrumental blanks of single-point method were higher. The correction method proposed was to use multipoint-corrected data when below the determined threshold, and use single-point results when beyond that threshold. The effectiveness of this correction method was supported by correlation with optical data.
Reference Key
zheng2014atmospherica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;G. J. Zheng;Y. Cheng;K. B. He;F. K. Duan;Y. L. Ma
Journal bioorganic & medicinal chemistry
Year 2014
DOI
10.5194/amt-7-1969-2014
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.