Validation of Wired and Wireless Interconnected Body Sensor Networks.
Clicks: 239
ID: 23264
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
82.0
/100
239 views
190 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1,071 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Current medical facilities usually lead to a very high cost especially for developing countries, rural areas and mass casualty incidents. Therefore, advanced electronic health systems are gaining momentum. In this paper, we first compared our novel off the shelf experimental wired Body Sensor Networks (BSN), that is, Digital First Aid (DigiAID) with the existing commercial product called as Hexoskin. We showed the viability of DigiAID through extensive real measurements during daily activities by both male and females. It was found that the major hurdle was wires to be worn by the subjects. Accordingly, we proposed and characterized the wireless DigiAID platform for wireless BSN (WBSN). Understanding the effect of body movements on wireless data transmission in WBSN is also of major importance. Therefore, this paper comprehensively evaluates and analyzes the impact of body movements, (a) to ensure transmission of data at different radio power levels and (b) its impact on the topology of the WBSN. Based on this we have proposed a dynamic power control algorithm that adapts the transmitting power according to the packet reception in an energy efficient manner. The results show that we have achieved substantial power savings at various nodes attached to the human body.
| Reference Key |
talpur2019validationsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Talpur, Anum;Shaikh, Faisal Karim;Baloch, Natasha;Felemban, Emad;Khelil, Abdelmajid;Alam, Muhammad Mahtab; |
| Journal | sensors |
| Year | 2019 |
| DOI |
E3697
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.