disinfection of needleless connector hubs: clinical evidence systematic review
Clicks: 161
ID: 232074
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
161 views
36 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #34 of 56 articles by views in Veterinary parasitology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background. Needleless connectors (NC) are used on virtually all intravascular devices, providing an easy access point for infusion connection. Colonization of NC is considered the cause of 50% of postinsertion catheter-related infections. Breaks in aseptic technique, from failure to disinfect, result in contamination and subsequent biofilm formation within NC and catheters increasing the potential for infection of central and peripheral catheters. Methods. This systematic review evaluated 140 studies and 34 abstracts on NC disinfection practices, the impact of hub contamination on infection, and measures of education and compliance. Results. The greatest risk for contamination of the catheter after insertion is the NC with 33–45% contaminated, and compliance with disinfection as low as 10%. The optimal technique or disinfection time has not been identified, although scrubbing with 70% alcohol for 5–60 seconds is recommended. Studies have reported statistically significant results in infection reduction when passive alcohol disinfection caps are used (48–86% reduction). Clinical Implications. It is critical for healthcare facilities and clinicians to take responsibility for compliance with basic principles of asepsis compliance, to involve frontline staff in strategies, to facilitate education that promotes understanding of the consequences of failure, and to comply with the standard of care for hub disinfection.
| Reference Key |
moureau2015nursingdisinfection
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Nancy L. Moureau;Julie Flynn |
| Journal | Veterinary parasitology |
| Year | 2015 |
| DOI |
10.1155/2015/796762
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.