the effects of geometry and operational conditions on gas holdup, liquid circulation and mass transfer in an airlift reactor
Clicks: 204
ID: 231533
2003
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
8.7
/100
29 views
29 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
In airlift reactors transport phenomena are achieved by pneumatic agitation and circulation occurs in a defined cyclic pattern through a loop. In the present work, the effect of geometrical relations on gas holdup and liquid velocity, and consequently on the gas-liquid mass transfer coefficient, was studied in a 6-liter airlift bioreactor with A D/A R = 0.63; A D, downcomer cross-sectional area, and A R, riser cross-sectional area. Measurements of the volumetric oxygen transfer coefficient (kLa) were taken in a water-air system using a modified sulfite oxidation method. Different conditions were examined by varying parameters such as superficial air velocity in the riser (U GR), bottom clearance (d1) and top clearance (d2). It was observed from the experimental results that d1 and d2 have a remarkable effect on kLa values. The effect is due to their influence on gas holdup and liquid velocity, consequently affecting kLa. Superficial air velocity in the riser (U GR) ranged from 0.0126 to 0.0440 m.s-1 and kLa varied between 40 to 250 h-1, whereas gas holdup (e) reached values up to 0.2. The volumetric oxygen transfer coefficient (kLa), gas holdup in the riser (eR) and downcomer (eD) and superficial liquid velocity in the riser (U LR) for all the geometrical relations were successfully correlated with dimensionless numbers, namely, the Sherwood number (Sh) and the Froude number (Fr) as well as with geometrical relations such as the bottom space ratio (B = d1/D D) and top space ratio (T = (d2 + D D)/D D).
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (243 words).
Try re-searching for a better abstract.
| Reference Key |
e.r.2003brazilianthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Gouveia E.R.;Hokka C.O.;Badino-Jr A.C. |
| Journal | database and network journal |
| Year | 2003 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.