substituição racional de hidrômetros em sistemas de abastecimento de água (doi:10.5216/reec.v9i3.31378)
Clicks: 8
ID: 231464
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
2.1
/100
8 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #11 of 12 articles by views in journal of economic perspectives
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
RESUMO: O presente trabalho avaliou o efeito da submedição em 862 hidrômetros de uma cidade do interior paulista com 75.000 ligações ativas de água, objetivando a criação de uma proposta para identificar os hidrômetros com pior desempenho metrológico, indicando a sequência de substituição. Para isso, foram avaliados medidores classe metrológica A e B, segregados por fabricante, ano e volume totalizado. Todos os hidrômetros foram submetidos a teste em bancada em três vazões, 15 L/h (classe B) ou 30 L/h (classe A), 75 L/h (classe A e B) e 750L/h (classe A e B). Os resultados apontaram que 37,1% foram reprovados registrando leituras menores que a leitura de referência, com submedição variando de -0,7 a 31,1%. Foi observado que alguns hidrômetros mais antigos estavam com melhores desempenhos metrológicos que os mais novos, podendo, caso fosse realizada uma substituição sem critérios, haver aumento de perda aparente com uma redução de receita ao invés de benefícios. Este estudo possibilitou a criação de uma sequência de grupos de hidrômetros que apresentou menor desempenho metrológico, e sua substituição acarretará um aumento no volume micromedido, reduzindo o índice de perdas aparente e, consequentemente aumentando o volume faturado. ABSTRACT: This study evaluated the effect of under-metering in 862 water meters in a countryside city of São Paulo State, with 75,000 active water connections. It was evaluated metrological class A and B water meters, separated by manufacturer, year and totalized volume. All water meters were subjected to bench tests in three flows, 15 L/ h (class B) or 30 L/ h (class A), 75 L/ h (class A and B) and 750L/ h (A and B class). The results showed that 37.1% were disapproved by registering reading lower than the reference, with sub-metering ranging from -0.7 to 31.1%. It was observed that some older water meters had better metrological performances than the newest ones, and if a replacement without criteria be held, it may result increase in an apparent losses with a reduction of incoming rather than benefits. This study enabled the creation of a sequence of groups of lowest water meter metrological performance, and its replacement will result in an increase in micro-measured volume, reducing the rate of apparent losses and, consequently, increasing the amount billed.
| Reference Key |
scalize2014reec:substituio
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Paulo Sérgio Scalize;Wellington Cyro de Almeida Leite;Marcus André Siqueira Campos |
| Journal | journal of economic perspectives |
| Year | 2014 |
| DOI |
10.5216/reec.v9i3.31378
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.