can base excess and anion gap predict lactate level in diagnosis of septic shock?

Clicks: 207
ID: 230941
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 10 articles by views in bmj (online)

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Werapon Pongmanee,1 Veerapong Vattanavanit2 1Department of Internal Medicine, 2Division of Critical Care Medicine, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand Background: Lactate measurement is the key component in septic shock identification and resuscitation. However, point-of-care lactate testing is not widely used due to the lack of access to nearby test equipment. Biomarkers such as serum lactate, anion gap (AG), and base excess (BE) are used in determining shock in patients with seemingly normal vital signs. Purpose: We aimed to determine if these biomarkers can be used interchangeably in patients with septic shock in the emergency setting. Patients and methods: A prospective observational cohort study was undertaken at a tertiary hospital in southern Thailand. Baseline point-of-care BE, AG, and serum lactate were recorded in all patients presenting with septic shock at the emergency department. Overall correlations including area under the receiver operating characteristic curve (AUROC) for both BE and AG to predict serum lactate level were calculated. Results: One hundred and fifteen patients were enrolled. Pearson correlation of serum lactate to BE was -0.59 (r2 = 0.35; 95% confidence interval [CI], -0.69 to -0.44; P < 0.001) and BE to AG was -0.67 (r2 = 0.49; 95% CI, -0.76 to -0.55; P < 0.001), and serum lactate to AG was 0.64 (r2 = 0.41; 95% CI, 0.52 to 0.74; P < 0.001). A cut-off point of 15.8 for AG identified a lactate level ≥2 mmol/L (sensitivity, 71.4%; specificity, 80.7%; and AUROC, 0.76), and the best cut-off value to predict a lactate level ≥4 mmol/L was 18.5 (sensitivity, 64.2%; specificity, 85.5%; and AUROC 0.78). Conclusion: In patients with septic shock, lactate and AG showed a strong correlation with each other, whereas lactate and BE showed a moderate correlation with each other. Thus, these biomarkers can be used interchangeably to help determine septic shock earlier in patients. Keywords: base excess, anion gap, lactate, septic shock 
Reference Key
w2017opencan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Pongmanee W;Vattanavanit V
Journal bmj (online)
Year 2017
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.