identification of the most effective point of connection for battery energy storage systems focusing on power system frequency response improvement

Clicks: 122
ID: 229473
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #454 of 526 articles by views in acs combinatorial science

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
With the massive penetration of intermittent generation (wind and solar), the reduction of Electrical Power Systems’ (EPSs) inertial frequency response represents a new challenge. One alternative to deal with this scenario may be the application of a Battery Energy Storage System (BESS). However, the main constraint for the massive deployment of BESSs is the high acquisition cost of these storage systems which in some situations, can preclude their use in transmission systems. The main goal of this paper is to propose a systematic procedure to include BESSs in power system aiming to improve the power system frequency response using full linear models and geometric measures. In this work, a generic battery model is developed in a two-area test system with assumed high wind penetration and full conventional generators models. The full power system is linearized, and the geometric measures of controllability associated with of the frequency regulation mode are estimated. Then, these results are used to identify the most effective point of connection for a BESS aiming at the improvement of the power system frequency response. Nonlinear time-domain simulations are carried out to evaluate and validate the results.
Reference Key
pieroni2018energiesidentification Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Thiago Pieroni;Daniel Dotta
Journal acs combinatorial science
Year 2018
DOI
10.3390/en11040763
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.