to compare time-weighted graphs to evaluate the inclination of the acetabular component of patients who had total hip replacement surgery

Clicks: 88
ID: 228141
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,174 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Time-weighted graphs are used to detect small shifts in statistical process control. The aim of this study is to evaluate the inclination of the acetabular component with CUmulative SUM (CUSUM) chart, Moving Average (MA) chart, and Exponentially Weighted Moving Average (EWMA) chart. The data were obtained directly from thirty patients who had undergone total hip replacement surgery at Ondokuz Mayis University, Faculty of Medicine. The inclination of the acetabular component of these people, after total hip replacement, was evaluated. CUSUM chart, Moving Average chart, and Exponentially Weighted Moving Average were used to evaluate the quality control process of acetabular component inclination. MINITAB Statistical Software 15.0 was used to generate these control charts. The assessment done with time-weighted charts revealed that the acetabular inclination angles were settled within control limits and the process was under control. It was determined that the change within the control limits had a random pattern. As a result of this study it has been obtained that time-weighted quality control charts which are used mostly in the field of industry can also be used in the field of medicine. It has provided us with a faster visual decision.
Reference Key
tomak2015biomedto Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Leman Tomak;Yuksel Bek;Yılmaz Tomak
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2015
DOI
10.1155/2015/129610
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.