a new ion selective electrode method for determination of oseltamivir phosphate (tamiflu) and its pharmaceutical applications

Clicks: 185
ID: 227633
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #139 of 167 articles by views in Behavioural brain research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Oseltamivir phosphate (OP) is an antiviral drug that is used in the treatment and prophylaxis of both influenza A and influenza B. It is effective against all known influenza viruses that can infect humans, including pandemic influenza viruses and may be the most appropriate antiviral option against avian influenza caused by H5N1 virus. Tamiflu, the registered trademark used under exclusive license by Roche laboratories with OP as active pharmaceutical ingredient, is considered the best treatment for the bird flu disease. The construction and electrochemical response characteristics of poly vinyl chloride (PVC) membrane sensors for the determination of (OP) were described. The sensors are based on the use of the ion association complexes of (OP) cation with sodium tetraphenylborate–oseltamivir phosphate (NaTPB–OP), tungestosilisate–oseltamivir phosphate (TS–OP), phosphomolbdate–oseltamivir phosphate (PM–OP) and phosphotungestate–oseltamivir phosphate (PT–OP) as ion exchange sites in the PVC matrix. The performance characteristics of these sensors, which were evaluated according to IUPAC recommendations, reveal a fast, stable and linear response for (OP) over the concentration range from 10−5 to 10−2 mol L−1 with cationic slopes of 51.5 ± 0.3, 50 ± 0.5, 55 ± 0.2 and 50 ± 0.4 mV per decade across an extended OP concentration range from 1.0 × 10−6 to 1.0 × 10−2 mol L−1 for NaTPB–OP, TS–OP, PM–OP and PT–OP, respectively. The direct potentiometric determination of (OP) using the proposed sensors gave average recoveries of 99.9, 99.8, 99.9 and 99.7 for NaTPB–OP, TS–OP, PM–OP and PT–OP, respectively. The sensors are used for determination of (OP) in tablets. The method was successfully applied to commercial pharmaceuticals, Tamiflu. Validation of the method shows suitability of the proposed sensors for use in the quality control assessment of (OP). The developed method was found to be simple, accurate and precise when compared with a reported HPLC method.
Reference Key
hamza2017arabiana Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Salem M. Hamza;Nashwa M.H. Rizk;Hamdy A.B. Matter
Journal Behavioural brain research
Year 2017
DOI
10.1016/j.arabjc.2012.07.029
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.