reliability and validity measurement of sagittal lumbosacral quiet standing posture with a smartphone application in a mixed population of 183 college students and personnel

Clicks: 213
ID: 227593
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #18 of 34 articles by views in Journal of molecular biology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Accurate recording of spinal posture with simple and accessible measurement devices in clinical practice may lead to spinal loading optimization in occupations related to prolonged sitting and standing postures. Therefore, the purpose of this study was to establish the level of reliability of sagittal lumbosacral posture in quiet standing and the validity of the method in differentiating between male and female subjects, establishing in parallel a normative database. 183 participants (83 males and 100 females), with no current low back or pelvic pain, were assessed using the “iHandy Level” smartphone application. Intrarater reliability (3 same-day sequential measurements) was high for both the lumbar curve (ICC2,1: 0.96, SEM: 2.13°, and MDC95%: 5.9°) and the sacral slope (ICC2,1: 0.97, SEM: 1.61°, and MDC95%: 4.46°) sagittal alignment. Data analysis for each gender separately confirmed equally high reliability for both male and female participants. Correlation between lumbar curve and sacral slope was high (Pearson’s r=0.86, p<0.001). Between-gender comparisons confirmed the validity of the method to differentiate between male and female lumbar curve and sacral slope angles, with females generally demonstrating greater lumbosacral values (p<0.001). The “iHandy Level” application is a reliable and valid tool in the measurement of lumbosacral quiet standing spinal posture in the sagittal plane.
Reference Key
koumantakis2016advancesreliability Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;George A. Koumantakis;Maria Nikoloudaki;Sara Thacheth;Kalliroi Zagli;Konstantina Bitrou;Andreas Nigritinos;Leon Botton
Journal Journal of molecular biology
Year 2016
DOI
10.1155/2016/3817270
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.