modelling of the response of acoustic piezoelectric resonators in biosensor applications – part 1: the general theoretical analysis
Clicks: 132
ID: 227269
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
132 views
19 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #12 of 22 articles by views in arabic literature in the post-classical period
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Acoustic piezoelectric resonators are widely used as precise analytical
chemistry tools for the real-time monitoring of a negligibly small amount of
surface-attached mass of biological components, in particular, in
environmental biosensor measurements. The surface acoustic wave (SAW)-based
sensors and the quartz crystal microbalance (QCM) compared in our work belong
to the leading group due to their considerable advantages. These
piezoelectric resonators are considered now as high-resolution analytical
tools allowing researchers to discriminate between components due to the
selective polymer coating on the resonator surface. The gravimetrical
measurements performed with the SAW-based or QCM sensors provide the
experimental data with high precision for the detection of surface mass for
the thin adsorbed layer rigidly attached to the oscillator surface. The new
challenge is the analysis of soft and biological materials, where the viscous
losses of energy can essentially influence measured characteristics. Modelling
is the important part of the analysis allowing researchers to quantify the
results of the experiments. The present work provides a general theory of SH-SAW devices probing soft and
biological materials. The results are compared with QCM-D operated in liquid
media.
| Reference Key |
voinova2015journalmodelling
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;M. V. Voinova |