microbubble-mediated ultrasound enhances the lethal effect of gentamicin on planktonic escherichia coli

Clicks: 170
ID: 225661
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #682 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Previous research has found that low-intensity ultrasound enhanced the lethal effect of gentamicin on planktonic E. coli. We aimed to further investigate whether microbubble-mediated low-intensity ultrasound could further enhance the antimicrobial efficacy of gentamicin. The planktonic E. coli (ATCC 25922) was distributed to four different interventions: control (GCON), microbubble only (GMB), ultrasound only (GUS), and microbubble-mediated ultrasound (GMUS). Ultrasound was applied with 100 mW/cm2 (average intensity) and 46.5 KHz, which presented no bactericidal activity. After 12 h, plate counting was used to estimate the number of bacteria, and bacterial micromorphology was observed with transmission electron microscope. The results showed that the viable counts of E. coli in GMUS were decreased by 1.01 to 1.42 log10 CFU/mL compared with GUS (P<0.01). The minimal inhibitory concentration (MIC) of gentamicin against E. coli was 1 μg/mL in the GMUS and GUS groups, lower than that in the GCON and GMB groups (2 μg/mL). Transmission electron microscopy (TEM) images exhibited more destruction and higher thickness of bacterial cell membranes in the GMUS than those in other groups. The reason might be the increased permeability of cell membranes for gentamicin caused by acoustic cavitation.
Reference Key
zhu2014biomedmicrobubble-mediated Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Han-Xiao Zhu;Xun-Zi Cai;Zhong-Li Shi;Bin Hu;Shi-Gui Yan
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2014
DOI
10.1155/2014/142168
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.