time-domain signal-averaged electrocardiogram in healthy german shepherd and boxer dogs

Clicks: 230
ID: 223587
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #151 of 276 articles by views in Environmental research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 276 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Signal-averaged electrocardiogram (SAECG) identifies ventricular late potentials (LP), low-amplitude electrical signals that are markers of slow cardiac conduction in fibrous myocardium, consisting in a predictive factor for sudden death in dogs at risk of sustained ventricular tachycardia. The aim of this study was to establish reference values of SAECG for German Shepherd and Boxer dogs. SAECG was performed in 19 German Shepherd and 28 Boxer client-owned dogs, and parameters analyzed were QRSd (duration of filtered QRS), LAS<40μV (duration of low-amplitude signals in terminal portion of filtered QRS) and RMS40 (root square of mean voltage over the last 40 milliseconds of filtered QRS), with two different filters (25-250 Hz and 40-250 Hz). Statistical analyses was achieved by T Student test (p<0.05) to identify differences between the two groups and between the values obtained with the two filters. No statistical difference was found in SAECG variables between the two breeds with the two different filters (p>0.05). Achieving normal values of SAECG in German Shepherd and Boxer dogs is important to further research late potentials in animals of these breeds with hereditary ventricular tachycardia or arrhythmogenic cardiomyopathy and identification of individuals at high risk of cardiac-related sudden death.
Reference Key
chamas2014arquivotime-domain Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;P.P.C. Chamas;V.M.C. Oliveira;F.L. Yamaki;M.H.M.A. Larsson
Journal Environmental research
Year 2014
DOI
10.1590/1678-41626148
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.