aksillere temperatuur vergelyk met timpaniese membraan temperatuur in kinders

Clicks: 6
ID: 223551
2000
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #792 of 812 articles by views in Materials (Basel, Switzerland)

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 812 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The purpose of the study was to measure the axillary temperature at three, six and nine minutes in a hundred children between the ages of one and twelve years who were selected in a non-random deliberate way, and to compare the measurements with the tympanic membrane temperature (golden standard) which was measured in the test persons at the same time. The results were described by sensitivity, specificity, limits of agreement, and predictive values. From some of the findings of the research it is apparent that the axillary temperature reading increased after measurement of three, six and nine minutes. A maximum temperature reading was reached after three minutes in only 9% of the test persons, in 25% after six minutes and in 66% after nine minutes. From the findings it is clear that the ranges that were used influenced the sensitivity of the measurements, and it would appear that the range 35,5°C to 37,2°C was the best range to measure pyrexia in the age group one to 12 years. The 9- minute measurement then had the highest sensitivity. However, the specificity of measurement in this range was lower. The conclusion was drawn that axillary temperature measurement is an acceptable method, with certain reservations, to use as screening method for pyrexia in emergency divisions or clinics.
Reference Key
greyling2000curationisaksillere Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;G Greyling;MJ Viljoen;G Joubert
Journal Materials (Basel, Switzerland)
Year 2000
DOI
10.4102/curationis.v23i3.701
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.