a comparison between tube surgery, nd:yag laser and diode laser cyclophotocoagulation in the management of refractory glaucoma

Clicks: 148
ID: 222674
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #860 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose. To compare the results of intraocular pressure (IOP) reduction by 3 treatment modalities, (a) glaucoma tube implants, (b) noncontact YAG laser cyclophotocoagulation (cycloYAG), and (c) contact transscleral diode laser cyclophotocoagulation (cyclodiode), in cases of advanced glaucoma refractory to alternative treatments. Methods. A consecutive group of 45 eyes that received cycloYAG were matched against two control groups of patients who had received tube surgery or cyclodiode, each control group having been derived from a database of patients. Results. Mean pretreatment IOP improved from 41.3, 38.6, and 32.0 mmHg for the tube, cycloYAG, and cyclodiode groups, respectively, to 16.4, 22.1, and 19.3 mmHg, respectively. Treatment success was achieved in 78%, 69%, and 71% of the tube, cycloYAG, and cyclodiode groups, respectively. Visual acuity deteriorated 2 or more Snellen lines in 16%, 7%, and 9% of the patients in the tube, cycloYAG, and cyclodiode groups, respectively. Complications included retinal detachment, hypotony, and phthisis. Conclusions. All 3 methods provided acceptable IOP lowering in the short and medium term. Control of IOP was best in patients receiving tube surgery. Cyclodiode and cycloYAG treatments were similarly effective in lowering IOP. Tube surgery was associated with a greater incidence of sight threatening complications.
Reference Key
bloom2013biomeda Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Philip A. Bloom;Colin I. Clement;Anthony King;Baha Noureddin;Kamal Sharma;Roger A. Hitchings;Peng T. Khaw
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2013
DOI
10.1155/2013/371951
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.