comparison of the clinical use of macintosh and miller laryngoscopes for orotracheal intubation by second-month nurse students in anesthesiology

Clicks: 361
ID: 222490
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #5 of 22 articles by views in journal of dinamika hukum

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aim. The aim of this study is to compare the clinical feasibility of Macintosh and Miller laryngoscopes for tracheal intubation in non-experienced users in anesthetized patients. Patients and Methods. 119 patients were randomized into the Macintosh group (59) and the Miller group (60). The primary outcome variable was successful tracheal intubation. The secondary outcome variables were number of insertion attempt, intubation time needed, total time to intubation, hemodynamic change and complications. Results. All patients were successfully intubated using the Macintosh, whereas 13 patients (21.6%) were failed with the Miller (𝑃<.001). The Macintosh significantly reduced the mean total time to intubation (𝑃<.001). There were significant differences in the mean blood pressure at 2 minutes after laryngoscope insertion, immediately, and 2 minutes after tracheal intubation and in the mean heart rate at the laryngoscope insertion, immediately, and at 2 minutes after tracheal intubation between the two groups. Overall complications in both were not significantly different. Conclusion. Orotracheal intubation using the Macintosh is an effective and safe technique in non-experienced hands with significantly increased success rate as well as decreased mean total time to intubation as compare to the Miller. However, these intubations only apply to selected patients deemed to have normal airways.
Reference Key
amornyotin2010anesthesiologycomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Somchai Amornyotin;Ungkab Prakanrattana;Phongthara Vichitvejpaisal;Thantima Vallisut;Neunghathai Kunanont;Ladda Permpholprasert
Journal journal of dinamika hukum
Year 2010
DOI
10.1155/2010/432846
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.