less expansion of short-pulse laser scars in panretinal photocoagulation for diabetic retinopathy
Clicks: 12
ID: 221958
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
3.3
/100
12 views
3 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #157 of 167 articles by views in chemical reviews
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Purpose. To compare the expansion rates of laser photocoagulation scars between the conventional laser and short-pulse laser using fundus autofluorescence (FAF). Methods. Retrospective chart review. Conventional laser was performed on 6 eyes of 6 patients, and short-pulse laser was performed on 11 eyes of 8 patients with diabetic retinopathy. FAF images were obtained by Optos® 200Tx (Optos, Dunfermline, Scotland, UK) at 1, 3, 6, and 12 months after treatment. The average area of 20 photocoagulation scars was measured by using ImageJ software. The expansion rates were calculated from the proportion of the averaged area against the optic disc area. Regression of retinopathy and central macular thickness were also evaluated. Results. The expansion rates of the conventional laser scars compared with the size at 1 month after treatment were 1.12 ± 0.08 (3 M), 1.27 ± 0.12 (6 M), and 1.39 ± 0.11 (12 M). The expansion rates of the short-pulse laser scars were 1.04 ± 0.05 (3 M), 1.09 ± 0.04 (6 M), and 1.13 ± 0.05 (12 M). The expansion rates of the short-pulse laser were significantly lower than those of the conventional laser (p<0.01). Conclusion. FAF images were useful to evaluate the changes in the photocoagulation scar sizes. The scars with the short-pulse laser showed lower expansion rates than those of the conventional laser.
| Reference Key |
higaki2018journalless
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Masahiko Higaki;Miho Nozaki;Munenori Yoshida;Yuichiro Ogura |
| Journal | chemical reviews |
| Year | 2018 |
| DOI |
10.1155/2018/9371895
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.