preliminary evaluation of an algorithm to minimize the power error selection of an aspheric intraocular lens by optimizing the estimation of the corneal power and the effective lens position

Clicks: 518
ID: 221085
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #8 of 133 articles by views in journal of fungi

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
AIM: To evaluate the refractive predictability achieved with an aspheric intraocular lens(IOL)and to develop a preliminary optimized algorithm for the calculation of its power(PIOL).

METHODS: This study included 65 eyes implanted with the aspheric IOL LENTIS L-313(Oculentis GmbH)that were divided into 2 groups: 12 eyes(8 patients)with PIOL≥23.0 D(group A), and 53 eyes(35 patients)with PIOL<23.0 D(group B). The refractive predictability was evaluated at 3mo postoperatively. An adjusted IOL power(PIOLadj)was calculated considering a variable refractive index for corneal power estimation, the refractive outcome obtained, and an adjusted effective lens position(ELPadj)according to age and anatomical factors.

RESULTS: Postoperative spherical equivalent ranged from -0.75 to +0.75 D and from -1.38 to +0.75 D in groups A and B, respectively. No statistically significant differences were found in groups A(P=0.64)and B(P=0.82)between PIOLadj and the IOL power implanted(PIOLReal). The Bland and Altman analysis showed ranges of agreement between PIOLadj and PIOLReal of +1.11 to -0.96 D and +1.14 to -1.18 D in groups A and B, respectively. Clinically and statistically significant differences were found between PIOLadj and PIOL obtained with Hoffer Q and Holladay I formulas(P<0.01).

CONCLUSION: The refractive predictability of cataract surgery with implantation of an aspheric IOL can be optimized using paraxial optics combined with linear algorithms to minimize the error associated to the estimation of corneal power and ELP.

Reference Key
pi&#xf1;ero2016guojipreliminary Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;David P. Pi&#xF1;ero;Vicente J. Camps;María L. Ram&#xF3;n;Verónica Mateo;Roberto Soto-Negro
Journal journal of fungi
Year 2016
DOI
10.3980/j.issn.1672-5123.2016.6.01
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.