prognostication in pulmonary arterial hypertension with submaximal exercise testing
Clicks: 291
ID: 219579
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
291 views
59 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #9 of 26 articles by views in Technology in society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction: The submaximal exercise test (SET), which gives both a measure of exercise tolerance, as well as disease severity, should be a more robust functional and prognostic marker than the six-minute walk test (6MWT). This study aimed to determine the prognostic value of SET as predicted by the validated REVEAL (Registry to Evaluate Early and Long-Term Pulmonary Artery Hypertension Disease Management) registry risk score (RRRS). Methods: Sixty-five consecutive patients with idiopathic and associated pulmonary arterial hypertension (PAH) underwent right-heart catheterization, echocardiogram, 6MWT and a three-minute SET (Shape-HF™). Analyses explored the association between SET variables and prognosis predicted by the RRRS. Results: Although multiple SET variables correlated with the RRRS on univariate analyses, only VE/VCO2 (r = 0.57, p < 0.0001) remained an independent predictor in multivariate analysis (β = 0.05, p = 0.0371). Additionally, the VE/VCO2 was the most discriminatory (area under receiver operating characteristic curve, 0.84) in identifying the highest-risk category (RRRS ≥ 10), with an optimal cut-off of 40.6, resulting in a high sensitivity (92%) and negative-predictive value (97%), but a lower specificity (67%). Conclusion: SETs, particularly the VE/VCO2, appear to have prognostic value when compared to the RRRS. If validated in prospective trials, SET should prove superior to the 6MWT or the RRRS, with significant implications for both future clinical trials and clinical practice.
| Reference Key |
khatri2015diseasesprognostication
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Vinod Khatri;Jennifer E. Neal;Charles D. Burger;Augustine S. Lee |
| Journal | Technology in society |
| Year | 2015 |
| DOI |
10.3390/diseases3010015
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.