sensitivity and resolution capacity of electrode configurations
Clicks: 128
ID: 219450
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
128 views
31 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #34 of 36 articles by views in organometallics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This paper reviews the geological conditions, data density, and acquisition geometry that have direct influence on the sensitivity and resolution capacity of several electrode configurations. The parameters appreciate the effectiveness of automated multichannel system which has evolved several electrode arrays that are cost effective, reduction in survey time, high sensitivity, and resolution capacity in 2D and 3D resistivity tomographies. The arrays are pole-pole, pole-dipole, pole-bipole, dipole-dipole, Wenner, Wenner-, , gradient, midpoint-potential-referred, Schlumberger, square, and Lee-partition arrays. The gradient array and midpoint-potential-referred are well suited for multichannel surveying and gradient array images are comparable to dipole-dipole and pole-dipole. 2D electrical resistivity surveys can produce out-of-plane anomaly of the subsurface which could be misleading in the interpretation of subsurface features. Hence, a 3D interpretation model should give more accurate results, because of the increase in the reliability of inversion images and complete elimination of spurious features. Therefore, the reduction of anomaly effects and damping factor due to signal to noise ratio result in better spatial resolution image, thus enhancing its usage in environmental and engineering research.
| Reference Key |
okpoli2013internationalsensitivity
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Cyril Chibueze Okpoli |
| Journal | organometallics |
| Year | 2013 |
| DOI |
10.1155/2013/608037
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.