feasibility assessment of thermal management system for green power sources using nanofluid
Clicks: 77
ID: 217147
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
22.8
/100
77 views
11 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #405 of 443 articles by views in reproductive biology and endocrinology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 443 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A thermal management system using alumina (Al2O3)/water as the nanofluid for green power sources was experimentally assessed in this paper. Basic thermal principles and formulas were utilized to evaluate the performance of an air-cooled heat exchanger. The Al2O3/water nanofluid was produced at the concentrations of 0.5, 1.0, and 1.5 wt.%. The testing conditions of this experiments were above three concentrations, five coolant flow rates (0.8, 1.2, 1.6, 2.0, and 2.4 L/min.), and three heating powers (50, 100, and 150 W). Firstly, basic properties of nanoparticles were analyzed. Fundamental relationships of the Al2O3/water nanofluid with respect to temperatures and concentrations were measured such as: viscosity, density, and specific heat. Next, an innovative concept named efficiency factor (EF) was proposed to quantitatively evaluate the thermal system performance. The enhancement of thermal system performance compared with distilled water was then defined as an efficiency factor ratio (REF). The experimental results demonstrated that the efficiency factor ratios were optimal at low flow rate (0.8 L/min.) and low concentration (0.5%). Values of REF were all below 1.0 at high flow rates (1.2–2.4 L/min.). This research points out the direction of optimizing a thermal management system for green energy sources in the near future.
| Reference Key |
hung2013journalfeasibility
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Yi-Hsuan Hung;Jyun-Hong Chen;Tun-Ping Teng |
| Journal | reproductive biology and endocrinology |
| Year | 2013 |
| DOI |
10.1155/2013/321261
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.