An Open Source Automated Two-Bottle Choice Test Apparatus for Rats.
Clicks: 265
ID: 21697
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
70.7
/100
265 views
189 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #3 of 3 articles by views in hardwarex
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Two-bottle choice tests are a widely used paradigm in rodents to determine preference between two liquids, with utility for testing animal models of addiction, depression and anhedonia. The following paper describes a 3D-printed, Arduino controlled two-bottle choice test that automatically reads and records drinking behavior in rats to allow for detailed analysis of their drinking microstructure. While commercial products exist use lickometers to measure the microstructure of licking, this design uniquely incorporates hydrostatic depth sensors to allow for real-time volumetric measurements in addition to traditional beam break lick sensing, allowing for licking and drinking microstructure analysis. The goal of this design is to provide a user friendly, affordable apparatus that can study unique, complex behaviors without requiring the purchase of specialized scientific equipment or software. Its applications range from studying alcohol preference in animal models of addiction to sucrose preference in motivational deficits and reward evaluation. This design costs less than $180 CAD to build with decreased cost on each additional device. This design has been successfully tested for accuracy and validated using alcohol preference as an example. The apparatus showed consistency between drinking bouts and volume consumed and is shown to be accurate to ±0.086 ml of the actual volume. This design makes using the two-bottle choice paradigm more accurate, while also making its data more robust and informative while allowing for microstructure analysis of both licking behavior and volume consumed.
| Reference Key |
frie2019anhardwarex
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Frie, Jude A;Khokhar, Jibran Y; |
| Journal | hardwarex |
| Year | 2019 |
| DOI |
e00061
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.