highly sensitive reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor for high temperature applications
Clicks: 118
ID: 216259
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
118 views
4 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #158 of 205 articles by views in BMC infectious diseases
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 205 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor was proposed in this paper for high temperature applications. The reentrant cavity was analyzed from aspects of distributed model and equivalent lumped circuit model, on the basis of which an optimal sensor structure integrated with a rectangular microstrip patch antenna was proposed to better transmit/receive wireless signals. In this paper, the proposed sensor was fabricated with high temperature resistant alumina ceramic and silver metalization with weld sealing, and it was measured in a hermetic metal tank with nitrogen pressure loading. It was verified that the sensor was highly sensitive, keeping stable performance up to 300 kPa with an average sensitivity of 981.8 kHz/kPa at temperature 25°C, while, for high temperature measurement, the sensor can operate properly under pressure of 60–120 kPa in the temperature range of 25–300°C with maximum pressure sensitivity of 179.2 kHz/kPa. In practical application, the proposed sensor is used in a method called table lookup with a maximum error of 5.78%.
| Reference Key |
lu2017journalhighly
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Fei Lu;Yanjie Guo;Qiulin Tan;Tanyong Wei;Guozhu Wu;Haixing Wang;Lei Zhang;Xiaowei Guo;Jijun Xiong |
| Journal | BMC infectious diseases |
| Year | 2017 |
| DOI |
10.1155/2017/3417562
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org