determination of aflatoxin m1 and chloramphenicol in milk based on background fluorescence quenching immunochromatographic assay
Clicks: 262
ID: 216059
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
262 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #88 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Harsh demanding has been exposed on the concentration of aflatoxin M1 (AFM1) and chloramphenicol (CAP) in milk. In this study, we developed a new method based on background fluorescence quenching immunochromatographic assay (bFQICA) to detect AFM1 and CAP in milk. The detection limit for AFM1 was 0.0009 ng/mL, while that for the CAP was 0.0008 ng/mL. The assay variability was determined with 3 AFM1 standards (i.e., 0.25 ng/mL, 0.5 ng/mL, and 1.0 ng/mL), and the actual detection value was 0.2497, 0.5329, and 1.0941, respectively. For the assay variability of 3 CAP standards (i.e., 0.10 ng/mL, 0.30 ng/mL, and 0.50 ng/mL), the actual detection value was 0.0996, 0.3096, and 0.4905, respectively. The recovery rate of AFM1 was 99.7%–101.7%, while that for CAP was 95.3%–97.6%. For the test stability, AFM1 and CAP showed satisfactory test stability even at month 5. Compared with the sensitivity of liquid chromatography-mass spectrometry (LC-MS) method, no statistical difference was noticed in results of the bFQICA. Our method is convenient for the detection of AFM1 and CAP in milk with a test duration of about 8 minutes. Additionally, an internal WiFi facility is provided in the system allowing for quick connection and storage in the intelligent cell phone.
| Reference Key |
wu2017biomeddetermination
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Xiaoxia Wu;Xiaofeng Tian;Lihua Xu;Jiutong Li;Xinxia Li;Yuwen Wang |
| Journal | spectrochimica acta - part a: molecular and biomolecular spectroscopy |
| Year | 2017 |
| DOI |
10.1155/2017/8649314
|
| URL | |