seismic performance evaluation of multistory reinforced concrete moment resisting frame structure with shear walls

Clicks: 177
ID: 216002
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #624 of 935 articles by views in journal of physics: conference series

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 935 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper is intended to evaluate the seismic performance of a twelve-story reinforced concrete moment-resisting frame structure with shear walls using 3D finite element models according to such seismic design regulations as Federal Emergency Management Agency (FEMA) guideline and seismic building codes including Los Angeles Tall Building Structural Design Council (LATBSDC) code. The structure is located in Seismic Zone 4, considered the highest-seismic-risk classification established by the U.S. Geological Survey. 3D finite element model was created in commercially available finite element software. As part of the seismic performance evaluation, two standard approaches for the structure seismic analysis were used; response spectrum analysis and nonlinear time-history analysis. Both approaches were used to compute inter-story drift ratios of the structure. Seismic fragility curves for each floor of the structure were generated using the ratios from the time history analysis with the FEMA guideline so as to evaluate their seismic vulnerability. The ratios from both approaches were compared to FEMA and LATBSDC limits. The findings revealed that the floor-level fragility mostly decreased for all the FEMA performance levels with an increase in height and the ratios from both approaches mostly satisfied the codified limits.
Reference Key
seo2015sustainabilityseismic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Junwon Seo;Jong Wan Hu;Burte Davaajamts
Journal journal of physics: conference series
Year 2015
DOI
10.3390/su71014287
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.