self-monitoring application of conductive asphalt concrete under indirect tensile deformation
Clicks: 320
ID: 215876
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
320 views
30 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #6 of 22 articles by views in psilogos
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Conductive asphalt concrete has excellent self-monitoring abilities for internal damage and attractive application prospects. By studying the resistance and strain changes under indirect tensile deformation, three distinct stages of output resistivity changes are observed during the destruction of the specimen. In the initial loading stages, contact between the mixture particles tightens because the specimen under loading forms a more conductive path, and the resistivity decreases significantly. In the second stage, asphalt concrete deforms smoothly; small changes in the interior of the asphalt concrete also correspond to small changes in resistivity. In the final stage, because of the progressive development of cracks in asphalt concrete, the specimens are destroyed, and the conductive paths are also seriously damaged, significantly increasing resistivity. This change in the resistivity value exceeds 50%. Conductive asphalt concrete also has a good self-monitoring ability regarding the strain caused by the applied stress. The unit strain corresponding to changes in resistivity is greater when graphite content is lower. CT (Computer Tomography)identification can confirm that changes in resistivity are caused by material changes in the interior due to fatigue failure. The decrease or increase in resistivity is the result of a decrease or increase in the internal porosity of the material.
| Reference Key |
liu2015caseself-monitoring
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Xiaoming Liu;Zhihong Nie;Shaopeng Wu;Cui Wang |
| Journal | psilogos |
| Year | 2015 |
| DOI |
10.1016/j.cscm.2015.07.002
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.