comparison of the bone harvesting capacity of an intraoral bone harvesting device and three different implant drills

Clicks: 84
ID: 215447
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #1,195 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The aim of the present study was to compare bone-collecting capacity of bone harvesting device and minimally irrigated low-speed drilling using three implant systems. One bone harvesting device and three commercially available drill systems were compared using the osteotomies on bovine rib bones. The amount of the collected bone particle and particle size (<500 μm: small, 500–1000 μm: medium, and >1000 μm: large) were measured. Total wet (1.535±0.232 mL) and dry volume (1.147±0.425 mL) of the bone particles from bone harvesting device were significantly greater than three drill systems (wet volume: 1.225±0.187–1.27±0.29 mL and dry volume: 0.688±0.163–0.74±0.311 mL) (P<0.05). In all groups, the amount of large sized particles in wet and dry state was the greatest compared to that of medium and small particles. The dry weight of the bone particles showed the same tendency to volumetric measurement. In conclusion, total bone particles and large sized particles (>1000 μm) were harvested significantly greater by bone harvesting device than minimally irrigated low-speed drilling. The composition of particle size in all harvesting methods was similar to each other.
Reference Key
lim2017biomedcomparison Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Hyun-Chang Lim;Kyung-In Ha;Ji-Youn Hong;Ji-Young Han;Seung-Il Shin;Seung-Yun Shin;Yeek Herr;Jong-Hyuk Chung
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2017
DOI
10.1155/2017/7819080
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.