comparative study of shear bond strength of glass ionomer to hypoplastic enamel and normal enamel

Clicks: 207
ID: 215013
2000
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #74 of 133 articles by views in 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction. Glass ionomer materials have been, used for years as liners, bases and temporary restoration for children. Their bonding properties allow temporization, which would be difficult with conventional cements of restorative materials. The desirable properties include easy and rapid application, fluoride release, biocompatibility and adhesion to dentin and enamel tend to be used in children specially for precooperative or handicapped children and preclude the need for treatment using general anesthesia of sedation in this research, shear bond strength of glass ionomer in two groups, including normal group and hypoplastic enamel group is tested. Methods. For this purpose, 2 groups each including 12 samples of normal anterior deciduous teeth and hypoplastic anterior deciduous teeth (with attention to hypoplastic indices) were chosen. The labial surface of teeth were prepared with medium and fine size discs, chem fil glass ionomer cement was bonded to prepared surfaces of teeth, and then samples were fixed in special site of self curing acrylic. The specimens were tested with a model 4031 instron machine. A shear load was applied to the base of the bonded glass ionomer cylinder with a knife edge rod (width, 0.5 mm) at a cross head speed of 0.5 mm/mm. Results. The mean of obtained sbs for 2 groups was 16.35 and 11.63 KGF/mm2. Conclusions. Statistical analysis of the results showed significant defferences between studied groups. But with attention to desirable properties, application of glass ionomer cement in hypoplastic defects of enamel in children is recommended.
Reference Key
mortazavi2000journalcomparative Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;S.H MORTAZAVI;M.R KHAMEH
Journal 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings
Year 2000
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.