a method for improved sciamachy co2 retrieval in the presence of optically thin clouds
Clicks: 138
ID: 214357
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
138 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #124 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An optimal estimation based retrieval scheme for satellite
based retrievals of XCO2 (the dry air column averaged
mixing ratio of atmospheric CO2) is presented enabling
accurate retrievals also in the presence of thin clouds. The
proposed method is designed to analyze near-infrared nadir
measurements of the SCIAMACHY instrument in the CO2
absorption band at 1580 nm and in the O2-A
absorption band at around 760 nm. The algorithm
accounts for scattering in an optically thin cirrus cloud
layer and at aerosols of a default profile. The scattering
information is mainly obtained from the O2-A band and
a merged fit windows approach enables the transfer of
information between the O2-A and the CO2
band. Via the optimal estimation technique, the algorithm is
able to account for a priori information to further constrain
the inversion. Test scenarios of simulated SCIAMACHY
sun-normalized radiance measurements are analyzed in order to
specify the quality of the proposed method. In contrast to
existing algorithms for SCIAMACHY retrievals, the systematic
errors due to cirrus clouds with optical thicknesses up to
1.0 are reduced to values below 4 ppm for most of
the analyzed scenarios. This shows that the proposed method has
the potential to reduce uncertainties of SCIAMACHY retrieved
XCO2 making this data product potentially useful for
surface flux inverse modeling.
| Reference Key |
reuter2010atmospherica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;M. Reuter;M. Buchwitz;O. Schneising;J. Heymann;H. Bovensmann;J. P. Burrows |
| Journal | bioorganic & medicinal chemistry |
| Year | 2010 |
| DOI |
10.5194/amt-3-209-2010
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.