vaginal fluid urea and creatinine in the diagnosis of premature rupture of membranes in resource limited community settings

Clicks: 441
ID: 213941
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #5 of 18 articles by views in excli journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract

Objective: Diagnosis of premature rupture of membranes (PROM) is difficult in equivocal cases with traditional methods. This study aimed to evaluate the reliability of vaginal washing fluid urea and creatinine for diagnosis of PROM and to determine the cut off value.
Materials and methods: The current study was a prospective case control. Women having gestational age of 28 to 42 weeks were divided into two equal groups: Fifty with history of leaking per vagina (study group) and an equal number with gestation matched none leaking (control group) were recruited. Data analysis was done by Student’s t-test, receiver operator curve and chi square test.
Results: The demographic data of both groups were comparable at the time of sampling (p > 0.05).Vaginal fluid urea and creatinine was significantly higher in study group (p < 0.001). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of vaginal fluid urea with a cut off value > 6mg/dl and creatinine with a cut off value of > 0.3 mg/dl to diagnose PROM were all more than 90%. The sensitivity, specificity, PPV, NPV and accuracy of amniotic fluid index (AFI) to diagnose PROM were 30%, 91.8%, 83.33%, 57.32% and 62 % respectively, with a cut-off value of ≤ 7 cm. The areas under the curves are 0.952 for creatinine, 0.999 for urea and 0.635 for AFI.
Conclusion: Detection of vaginal fluid urea and creatinine to diagnose PROM is a simple, reliable and rapid test. Introduction of this method into routine use even in low resource community setting is feasible, practical and cost effective.

Reference Key
begum2017journalvaginal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager